Table 16. OH radicals concentration (cm-3× 10-16).
U0 =10 m/s, 98-open, Tu0 =8%, rib - 3mm.
x,y (mm)
yx=35x=70x=95x=135x=165x=200†
1 0,360,200,250,21
2 0,720,030,060,230,340,17
3 2,950,930,460,520,12
4 2,192,081,53 0,150,66
5 0,861,932,330,631,550,56
6 0,501,541,951,482,540,50
7 0,291,211,551,462,841,16
8 0,130,381,391,382,770,80
9 0,020,180,720,892,451,19
100,000,070,450,472,341,22
11 0,000,000,152,04
12 0,351,211,16
13 0,580,520,23
14 0,05 0,35
16 0,24
18 0,10
20 0,00

The OH profiles change along with the increase of the distance from the channel inlet.Concentration maximum is shifted into the area of the oxidizer in relation to the flame, and its level is much lower than in the laminar flame of ethanol

Coordinate "y, mm" should be increased by 0.5 mm for data marked with dagger.