Table 5. Temperature profiles (T, K). U0 =10 m/s, 98-98,
rib - 3mm, Tu0 =1%
x,y (mm)

yx=32x=97x=162x=227x=292x=357
0 341341341341341341
1 140513261242116110971038
2 152015711590155514711373
3 135614931617168216541599
4 116113781547166217221726
5 964 12521449158416801733
6 773 11171339148015841666
7 573 976 1226137714931570
8 391 855 1123128013991469
9 314 752 1029118213011359
10296 657 928 108712031257
12293 527 752 91110331095
15293 396 532 674798 890
20293 308 349 420518 584
25293 294 299 315346 379
30293 293 293 295300 312

The readings were acquired using a platinum-platinum-rhodium thermocouple made from wire with a diameter of 50 um and were corrected for the radiation losses of the probe.