Table 7. Temperature profiles (T, K). U0 =10 m/s, 98-98,
rib - 3mm, Tu0 =8%
x,y (mm)

yx=32x=97x=162x=227x=292x=357
0 341341341341341341
1 14391105918914915758
2 18461466124312141193999
3 177815941435137713621206
4 151215821532147014751352
5 126414941557153015381435
6 1064 13591519155515551489
7 890 11841422153615401501
8 727 10231330150215011506
9 551 858 1225144114321489
10425 719 1132138813601422
12315 541 958 123612061300
15290 400 703 939 951 1089
20290 322 475 616 660 817
25290 297 353 412 463 590
30290 291 305 324 359 448
35290 290 290 293 305 355
40290 290 290 290 290 290

The readings were acquired using a platinum-platinum-rhodium thermocouple made from wire with a diameter of 50 um and were corrected for the radiation losses of the probe.