Table 9. Temperature profiles (T, K). U0 =10 m/s, 98-70,
rib - 3mm, Tu0 =1%
x,y (mm)

yx=32x=97x=162x=227x=292x=357
0 341341341341341341
1 136613961425142813761284
2 161515801548153915681573
3 155414081340133313461441
4 145612701172112911251241
5 126311341062970 980 1113
6 1012 966 922 875 893 987
7 850 857 842 820 828 907
8 708 763 781 777 786 842
9 566 663 720 739 748 790
10446 580 659 685 687 729
12337 475 548 564 578 634
15299 364 416 446 478 526
20293 301 310 323 348 384
25293 293 293 294 299 310
30293 293 293 293 293 294

The readings were acquired using a platinum-platinum-rhodium thermocouple made from wire with a diameter of 50 um and were corrected for the radiation losses of the probe.